Foul Sewer

Description

 

Foul Sewer

Choosing the Standard:

 

Qplast non pressure uPVC pipes are used for:

  • Underground Drainage;
  • Sewer Pipe;
  • Gully Pipe and
  • Storm Water.

 

Pipes and fittings are manufactured to the following standards:

 

Drainage is significantly improved by the use of rigid pipes that can be better set to run off water. Care must be taken to ensure drainage pipes are sloped so that silted water does not sit in the pipe allowing silt to dry and restrict future drainage.

 

BS EN 1401
  • Underground drainage, sewer and storm water pipes are available under BS EN 1401 in Terracotta (Orange Brown, RAL 8023) as follows:


In addition to the third party long-term type testing of all products, the following batch release or “routine” tests are carried out as standard:

Keyword: HRT – Heat Reversion Test; DCMT – Dichloromethane Test; VST – Vicat Softening Test

For the BSEN 1401 Fittings selection, see Qplast BSEN1401 fittings are compatible with DIN 19534 below.

 

DIN 19534
  • Underground drainage, sewer and storm water pipes are available under DIN 19534 in Terracotta (Orange Brown, RAL 8023) as follows:

 

In addition to the third party long-term type testing of all products, the following batch release or “routine” tests are carried out as standard:


Keyword: HRT – Heat Reversion Test; DCMT – Dichloromethane Test; VST – Vicat Softening Test

 

 

Choosing the SDR Rating:

SDR (or standard dimension ratio) is a method of rating a pipe’s durability against pressure by describing the correlation between the pipe dimension and the thickness of the pipe wall. The lower the SDR the more pressure it can withstand.

SDR for BS EN 1401

The British standard BS EN 1401 specify the requirement for pipes in the field of non-pressure underground drainage and sewerage, both outside the building structure and those buried in ground within the building structure. The following table illustrates the relationship between the pipe design and pressure rating for BS EN 1401.

SDR for DIN 19534

The following table illustrates the dimensional specifications in compliance with DIN 19534 standard.

 

Choosing the Fittings:

  • Qplast BSEN 1401 fittings are manufactured strictly in accordance with the BSEN standard and can be used with any compliant pipes but are recommended for Qplast pipes. Where fittings are not specified directly in the standard, these are manufactured to the same quality and rating as the standard and therefore are marked with the standard as is the market practice. Qplast BSEN1401 fittings are compatible with DIN 19534.
  • BSEN 1401 fittings are rated as ‘UD’ and ‘D’. UD fittings are for underground use proper. All Qplast fittings are rated UD. Beware: D rated fittings should not be used underground but only buried inside buildings.
  • Qplast BSEN 1401 fittings are fully compliant and rated as follows:

SDR: 41
SN: 4
Application: “UD” Underground

  • The following fittings are available under Qplast brand:

KEY WORDS
F/F: : Female/Female socket
M/F : Male/Female socket
RRJ : Rubber Ring Joint
SCJ : Solvent Cement Joint